| Material Specifications for Butt-Welding Fittings (ASTM) | |||||||||||
| ASTM A403/A403M-00a | |||||||||||
| Wrought Austenitic Stainless Steel Piping Fittings | |||||||||||
| Grade | Composition, % | ||||||||||
| C | Mn | P | S | Si | Ni | Cr | Mo | ||||
| WP 304 | 0.08 | 2.00 | 0.045 | 0.030 | 1.00 | 8.0-11.0 | 18.0-20.0 | - | |||
| WP 304L | 0.035 | 2.00 | 0.045 | 0.030 | 1.00 | 8.0-13.0 | 18.0-20.0 | - | |||
| WP 316 | 0.08 | 2.00 | 0.045 | 0.030 | 1.00 | 10.0-14.0 | 16.0-18.0 | 2.00-3.00 | |||
| WP 316L | 0.035 | 2.00 | 0.045 | 0.030 | 1.00 | 10.0-16.0 | 16.0-18.0 | 2.00-3.00 | |||
| GENERAL NOTE: | |||||||||||
| All values are maximum unless otherwise indicated. | |||||||||||
| Tensile and Elongation Requirements | WP304, WP316 | WP304L, WP316L | |||||||||
| Yield Strength, min, ksi [MPa] | 30[205] | 25[170] | |||||||||
| Tensile Strength, min, ksi [MPa] | 75[515] | 70[485] | |||||||||
| Elongation (1) | Longitudinal | 28 | 28 | ||||||||
| Transverse | 20 | 20 | |||||||||
| NOTE: (1) Standard round specimen, or small proportional specimen, or strip-type specimen, min % in 4D. | |||||||||||
| ASTM A420/A420M-00 | |||||||||||
| Piping Fittings of Wrought Carbon Steel and Alloy Steel for | |||||||||||
| Low Temperature Service | |||||||||||
| Grade | Composition, % | ||||||||||
| C | Mn | P | S | Si | Ni | Cu | Cr | Mo | V | Nb | |
| WPL6(1)(2) | 0.30 | 0.60-1.35 | 0.035 | 0.040 | 0.15-0.30 | 0.40 | 0.40 | 0.30 | 0.12 | 0.08 | 0.02 |
| WPL9 | 0.20 | 0.40-1.06 | 0.030 | 0.030 | - | 1.60-2.24 | 0.75-1.25 | - | - | - | - |
| GENERAL NOTE: | |||||||||||
| All values are maximum unless otherwise indicated. | |||||||||||
| NOTES: | |||||||||||
| (1) For each reduction of 0.01% C below 0.30%, an increase of 0.05% | |||||||||||
| Mn above 1.06% will be permitted, up to a maximum of 1.35%. | |||||||||||
| (2) Fittings made from forgings may have 1.35% max Mn. | |||||||||||
| Tensile Requirements | WPL6 | WPL9 | |||||||||
| Tensile Strength, min, ksi [MPa] | 60-85[415-585] | 63-88[435-610] | |||||||||
| Yield Strength, min, ksi [MPa] | 35[240] | 46[315] | |||||||||
| Wall thickness | Elongation Requirements | ||||||||||
| in | mm | Longitudinal | Transverse | ||||||||
| WPL6 | WPL9 | WPL6 | WPL9 | ||||||||
| Standard round specimen, or small | 22 | 20 | 12 | - | |||||||
| proportional specimen, min % in 4D | |||||||||||
| Rectangular Specimen for wall thickness | ³0.312 | ³7.94 | 30 | 28 | 16.5 | 18 | |||||
| 0.312in [7.94mm] and over, and for all small | |||||||||||
| sizes tested in full section; min % in 2in[50mm] | |||||||||||
| Rectangular Specimen for wall thickness | 0.281 | 7.14 | 28.5 | 26.5 | 15.5 | 17.0 | |||||
| less than 0.312in [7.94mm]; min % in | 0.250 | 6.35 | 27.0 | 25.0 | 14.5 | 16.0 | |||||
| 2 in[50mm] (0.5in [12.7mm] wide specimen) | 0.219 | 5.56 | 25.5 | 23.5 | - | - | |||||
| 0.188 | 4.76 | 24.0 | 22.0 | - | - | ||||||
| 0.156 | 3.97 | 22.5 | 20.5 | - | - | ||||||
| 0.125 | 3.17 | 21.0 | 19.0 | - | - | ||||||
| 0.094 | 2.38 | 19.5 | 17.5 | - | - | ||||||
| 0.062 | 1.59 | 18.0 | 16.0 | - | - | ||||||
| Where the wall thickness lies between two values above, the min elongation value is determined | |||||||||||
| by the following equations: | |||||||||||
| WPL6 | WPL9 | ||||||||||
| Longitudinal | E=48t+15.00 | E=48t+13.00 | |||||||||
| Transverse | E=32t+6.50 | E=32t+8.00 | |||||||||
| E = elongation in 2in[50mm], % | |||||||||||
| t = actual thickness of specimen, in[mm] | |||||||||||